0
Your Cart
Welcome to Agape Off Grid Solar

Features:

  • Extremely high number of charge/discharge cycles
  • > 10 Year lifespan with proper maintenance
  • Bluetooth monitoring
  • Wide operating temperature range
  • Unsurpassed high temperature performance
  • Green energy without metal contaminant
  • Low maintenance
  • High amp capacity
  • Stable output voltage
  • Little self-discharge
  • BMS safety protection. Each cell is fused and if for some unlikely situation a cell fails, this design will isolate the cell stopping any other damage and allows the battery to function safely
  • Convenient removable carry handle
  • Lightweight
  • 50, 100 & 200 Ah models available
  • Short circuit protected
  • Physical damage to battery case will not cause fire
  • Excessive thermal exposure will not cause a fire
  • Able to withstand over-charge/over-discharge without damage to the battery
  • Sophisticated Battery Management System (BMS)

Specifications:

Electrical SpecificationsLFP12V100B
Nominal Voltage12.8V
Nominal Capacity (at .5C, 77°F)100Ah
Minimum Capacity (at .5C, 77°F)95Ah
Expected Cycle Life>4000 cycles w/1C charge and discharge rate, at 77°F, 80% DOD
Operating Specifications
Charge MethodSmart charger, constant current, constant voltage
Charge Voltage Range (Max 14.6V)14.4 -14.6V
Continuous Charge Current100A Max
Charge Temperature32° F to 113° F
Continuous Discharge Current100A Max
Peak Instant Discharge Current (10 secs)200A
Over Voltage Shutdown15.2 +/-.5V
Discharge Cut-off Voltage8V =/- .5V
Discharge Temperature-4° F to 149° F
Storage Temperature-4° F to 113° F
Self Disharge (stored at 50% SOC)< 3%/month
Watt hours1280 watt hours
Physical Specifications
Battery Dimensions12.75″L x 6.50″W x 8.3″H 9″ with terminals
Weight28.5 lb.
Shipping Weight29.5 lb.
Group Size31
Battery post size5/16″ 8M 1.9″ long
BMS Operation
Over Charge ProtectionOver charge detection voltage:   3.8 +/- .05V
Over charge detection delay time:   .96 – 1.4s
Over charge release voltage:   3.60 +/-.05V
Maximum charge voltage:   3.65 +/-.05V
Over Discharge ProtectionOver discharge detection voltage:   2.0V +/- .05V
Over discharge detection delay time:   .96-1.4 s
Over discharge release voltage:   2.3V +/- .10V
Over Current ProtectionOver current detection delay time:   9 +/- 2ms
Over current release condition:   Cut load
Polarity Reverse ProtectionYes
Short Circuit ProtectionYes
UPC840271005812
Warranty10 Yr Manufacturer Defect. Prorated.

** Google and Apple app is AIMSBATB. 

Weight29.5 lbs

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.